Os malefícios da “Luva Chupeta” de látex na Unidade Neonatal

Autores

  • Janaína de Alencar Nunes Universidade Federal do Espírito Santo https://orcid.org/0000-0001-8561-5052
  • Mônica Barros Pontes Universidade Federal do Espírito Santo https://orcid.org/0000-0003-3629-236X
  • Sandra Willéia Martins Universidade Federal do Espírito Santo
  • Nállia Quirina Trindade de Coimbra Universidade Federal do Espírito Santo
  • Hilmara Aparecida Jesus Maioli Universidade Federal do Espírito Santo
  • Glaucia Cristina dos Santos França Sant’Ana Universidade Federal do Espírito Santo
  • Amábile de Sousa Cavalcante Universidade Federal do Espírito Santo https://orcid.org/0000-0002-8056-5305

DOI:

https://doi.org/10.23925/2176-2724.2023v35i2e58329

Palavras-chave:

Segurança do Paciente, Luvas Protetoras, Chupetas, Comportamento de Sucção, Unidades de Terapia Intensiva Neonatal, Aleitamento Materno

Resumo

Na Iniciativa Hospital Amigo da Criança-Neo foi proposto o uso da chupeta na Unidade Neonatal (UN) de modo terapêutico, e sempre com supervisão de um profissional de saúde. Mas observa-se que o aparato conhecido como “Luva Chupeta” fabricado com o uso de uma luva de látex está sendo utilizado como alternativa para acalentar o recém-nascido (RN). Apesar de poucos estudos, é evidente que esse dispositivo deve ser contraindicado na UN, uma vez que pode provocar alergia ao látex, transmitir infecções, provocar acidentes graves como aspiração laringotraqueal do algodão devido ao rompimento da luva de látex, e dependendo do tamanho do material, obstruir as vias aéreas, e levar a óbito. Além do mais, o dispositivo pode interferir negativamente no crescimento e no desenvolvimento craniofacial e causar prejuízos associados à amamentação e na saúde materno infantil. A substituição da “Luva Chupeta” por outras estratégias, até mesmo pela chupeta convencional ou ortodôntica, para lidar com a dor e situações de estresse do RN deve ser decisiva para evitar os riscos de acidentes graves. O Protocolo de uso de bicos, Protocolo de manejo da dor do RN, adoção do Método Canguru na UN para promoção do desenvolvimento e comportamento do RN, e a capacitação/monitoramento das práticas adotas pela Equipe Materno Infantil, quanto ao cuidado ofertado são alternativas mais complexas, mas que devem ser analisadas por aqueles que desejam oferecer confiabilidade aos seus processos institucionais.

Downloads

Não há dados estatísticos.

Metrics

Carregando Métricas ...

Biografia do Autor

Janaína de Alencar Nunes, Universidade Federal do Espírito Santo

Departamento de Fonoaudiologia, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Mônica Barros Pontes, Universidade Federal do Espírito Santo

Unidade Materno-Infantil, Hospital Universitário Cassiano Antonio de Moraes – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Sandra Willéia Martins, Universidade Federal do Espírito Santo

Unidade de Terapia Intensiva Neonatal, Hospital Universitário Cassiano Antônio de Moraes – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Nállia Quirina Trindade de Coimbra, Universidade Federal do Espírito Santo

Unidade de Terapia Intensiva Neonatal, Hospital Universitário Cassiano – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES)

Hilmara Aparecida Jesus Maioli, Universidade Federal do Espírito Santo

Unidade de Gestão da Qualidade e Segurança do Paciente, Hospital Universitário Cassiano Antonio de Moraes – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Glaucia Cristina dos Santos França Sant’Ana, Universidade Federal do Espírito Santo

Unidade de Terapia Intensiva Neonatal, Hospital Universitário Cassiano -HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES)

Amábile de Sousa Cavalcante, Universidade Federal do Espírito Santo

Graduação do Curso de Fonoaudiologia, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Referências

Maroja MCS, Silva ATMC, Carvalho AT. Iniciativa Hospital Amigo da Criança: uma análise a partir das concepções de profissionais quanto às suas práticas. Rev Port Saúde Pública. 2014; 32(1): 3-9. http://dx.doi.org/10.1016/j.rpsp.2014.02.002

Lau C. Breastfeeding Challenges and the Preterm Mother-infant Dyad: A Conceptual Model. Breastfeed Med. 2018; 13(1): 8-17. https://doi.org/10.1089/bfm.2016.0206

Bellù R, Condò M. Breastfeeding promotion: evidence and problems. Pediatr Med Chir. 2017; 39(2): 156. https://doi.org/10.4081/pmc.2017.156

McNair C, Campbell-Yeo M, Johnston C, Taddio A. Nonpharmacologic Management of Pain During Common Needle Puncture Procedures in Infants Current Research Evidence and Practical Considerations: An Update. Clin Perinatol. 2019; 46(4): 709-30. https://doi.org/10.1016/j.clp.2019.08.006

Nyqvist KH, Maastrup R, Hansen MN, Haggkvist AP, Hannula L, Ezeonodo A, et al. The Baby-friendly Hospital Initiative for Neonatal Wards. Core document with recommended standards and criteria. Nordic and Quebec Working Group; 2015. [cited 2022 Mai 23]; Available from: http://epilegothilasmo.gr/wp-content/uploads/2017/04/Neo_BFHI_Core_document_2015_Edition.pdf

Lubbe W, Ham-Baloyi WT. When is the use of pacifiers justifiable in the baby-friendly hospital initiative context? a clinician’s guide. BMC Pregnancy and Childbirth. 2017; 17(1): 130. https://doi.org/10.1186/s12884-017-1306-8

Ling HTB, Sum FHKMH, Zhang L, Yeung CPW, Li KY, Wong HM, et al. The association between nutritive, non-nutritive sucking habits and primary dental occlusion. BMC Oral Health. 2018; 18(1): 145. https://doi.org/10.1186/s12903-018-0610-7

Batista CL, Ribeiro VS, Nascimento MD, Rodrigues VP. Association between pacifier use and bottle-feeding and unfavorable behaviors during breastfeeding. J Pediatr. 2018; 94: 596-601. https://doi.org/10.1016/j.jped.2017.10.005

Sampaio RCT; Brito MBG; Siebra LGB; Gonçalves GKM; Feitosa DMA; Cabral KSSA; Pinto DM. Association between pacific use and breastfeeding interruption: A literature review. Brazilian Journal of health Review. 2020; 3(4): 7353-72. DOI:10.34119/bjhrv3n4-011

Rocha AD, Costa AM. Uso de luvas de látex em substituição às chupetas em Hospitais Amigos da Criança. Rev Ped SOPERJ. 2021; 21(3)98-106. DOI: http://dx.doi.org/10.31365/issn.2595-1769.v21i3p98-106

Dadalto ECV. Interação mãe-bebê e uso de chupeta no contexto do nascimento pré-termo: Cultura, representações sociais e processos proximais. [Tese]. Vitória (ES): Programa de Pós-graduação em Psicologia, Universidade Federal do Espírito Santo; 2014.

Associação Brasileira de Normas Técnicas. Norma Brasileira 10334 – segurança de chupetas. Rio de Janeiro: ABNT: 2003. 20p.

Agência Nacional de Vigilância Sanitária (ANVISA). Resolução nº 221. 05 de agosto de 2002. Publicada no D.O.U. de 06 de agosto de 2002.

Palosuo T, Antoniadou I, Gottrup F, Phillips P. Latex medical gloves: time for a reappraisal. Int Arch Allergy Imm 2011; 156(3): 234-46. doi: 10.1159/000323892

Álvarez D, Rojas H. Alergia al látex, puesta al día. Rev Chil Dermatología. 2016; 32(4): 192-96. DOI: http://dx.doi.org/10.31879/rcderm.v32i4.79

Kelly KJ, Sussman G. Latex allergy: where are we now and how did we get there? Internet J Allergy Clin Immunol Pract. 2017; 5(5): 1212–1216. DOI: 10.1016/j.jaip.2017.05.029

Ferreira AM, Andrade D. Avaliação Microbiológica de luvas de procedimento: considerações para seu uso na técnica de curativo. Rev. Enferm. UERJ. 2010; 18(2): 191-7.

Pereira CNP; Silva BVN; Menezes PHB; Pedro JPS; Silva NRD; Chagas HDS. Damage and benefits to the child’s health due to the use of pacifiers: what pediatricians need to know. Braz. J. of Develop. 2020; 6(12): 101520-31. DOI:10.34117/bjdv6n12-591

Marques AL; Alves MB; Firmo WDCA; Sabbadini OS. Avaliação da Integridade de Luvas de Procedimentos Novas Utilizando Micro-organismos. Ensaios e Ciência. 2021; 25(5): 809-14. DOI: https://doi.org/10.17921/1415-6938.2021v25n5-espp809-814

Thomas S, Agarwal M, Mehta G. Intraoperative glove perforation--single versus double gloving in protection against skin contamination. Postgrad Med J. 2001; 77(909): 458-60. doi: OI: 10.1136/pmj.77.909.458 .

Trindade JPDA; Serra JRD; Tipple AFV. Index of perforation of procedure/surgical gloves used by workers in the purging of a material and sterilization center. Texto & Contexto - Enfermagem. 2016,25(2), e1410015. Disponível em: <https://doi.org/10.1590/0104-07072016001410015>. Epub 7 Jul 2016. ISSN 1980-265X. https://doi.org/10.1590/0104-07072016001410015.

Oberg C; Schwartz JP; Zander GF; Ruan JD; Santos EB. Passagem de microrganismos através de luvas de procedimento e de luvas cirúrgicas antes de sua utilização. Rev. Odontol. UNESP. 2017; 36(2): 127-30.

Machado MB. Contribuições para a tecnovigilância das luvas de látex e a biossegurança. [Dissertação]. Ribeirão Preto (SP): Escola de Enfermagem de Ribeirão Preto, Universidade de São Paulo; 2019.

Pineda R; Luong A; Ryckman J; Smith J. Exploratory study found that pacifier use did not affect feeding performance in full-term newborn infants, but it was related to lower socioeconomic status. Acta paediatrica, Oslo. 2018; 107(5): 806-10. DOi: 10.1111/apa.14253.

Publicado

2023-08-02

Como Citar

Nunes, J. de A., Pontes, M. B., Martins, S. W., Coimbra, N. Q. T. de, Maioli, H. A. J., Sant’Ana, G. C. dos S. F., & Cavalcante, A. de S. (2023). Os malefícios da “Luva Chupeta” de látex na Unidade Neonatal. Distúrbios Da Comunicação, 35(2), e58329. https://doi.org/10.23925/2176-2724.2023v35i2e58329

Edição

Seção

Comunicações