Los efectos nocivos del “Guante Chupete” de látex em La Unidad Neonatal

Autores/as

  • Janaina de Alencar Nunes Universidade Federal do Espírito Santo https://orcid.org/0000-0001-8561-5052
  • Mônica Barros Pontes Universidade Federal do Espírito Santo https://orcid.org/0000-0003-3629-236X
  • Sandra Willéia Martins Universidade Federal do Espírito Santo
  • Nállia Quirina Trindade de Coimbra Universidade Federal do Espírito Santo
  • Hilmara Aparecida Jesus Maioli Universidade Federal do Espírito Santo
  • Glaucia Cristina dos Santos França Sant’Ana Universidade Federal do Espírito Santo
  • Amábile de Sousa Cavalcante Universidade Federal do Espírito Santo https://orcid.org/0000-0002-8056-5305

DOI:

https://doi.org/10.23925/2176-2724.2023v35i2e58329

Palabras clave:

Seguridad del Paciente, Guantes Protectores, Chupetes, Conducta en la Lactancia, Unidades de Cuidado Intensivo Neonatal, Lactancia Materna

Resumen

En la Iniciativa Hospital Amigo del Niño-Neo, se propuso terapéuticamente el uso del chupete en la Unidad Neonatal (UN), y siempre bajo la supervisión de un profesional de la salud. Pero se observa que el dispositivo conocido como “chupete Gluva”, fabricado con el uso de un guante de látex, está siendo utilizado como una alternativa para cuidar al recién nacido (NB). A pesar de los pocos estudios, es evidente que este dispositivo debe estar contraindicado en la NU, ya que puede causar alergia al látex, transmitir infecciones, ocasionar accidentes graves como aspiración laringotraqueal de algodón por rotura del guante de látex, y dependiendo de la El tamaño del material obstruye las vías respiratorias y provoca la muerte. Además, el dispositivo puede interferir negativamente con el crecimiento y desarrollo craneofacial y causar daños asociados con la lactancia materna y la salud maternoinfantil. La sustitución del “Dummy Glove” por otras estrategias, incluso el chupete convencional u ortodóncico, para hacer frente a las situaciones de dolor y estrés del RN debe ser determinante para evitar el riesgo de accidentes graves. El Protocolo de Uso del Pezón, el Protocolo de Manejo del Dolor del RN, la adopción del Método Canguro en la NU para promover el desarrollo y comportamiento del RN, y la capacitación/seguimiento de las prácticas adoptadas por el Equipo Materno Infantil, en cuanto a los cuidados ofrecidos, son más alternativas eficientes, complejas, pero que deben ser analizadas por quienes deseen brindar confiabilidad a sus procesos institucionales.

Descargas

Los datos de descargas todavía no están disponibles.

Métricas

Cargando métricas ...

Biografía del autor/a

Janaina de Alencar Nunes, Universidade Federal do Espírito Santo

Departamento de Fonoaudiologia, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Mônica Barros Pontes, Universidade Federal do Espírito Santo

Unidade Materno-Infantil, Hospital Universitário Cassiano Antonio de Moraes – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Sandra Willéia Martins, Universidade Federal do Espírito Santo

Unidade de Terapia Intensiva Neonatal, Hospital Universitário Cassiano Antônio de Moraes – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Nállia Quirina Trindade de Coimbra, Universidade Federal do Espírito Santo

Unidade de Terapia Intensiva Neonatal, Hospital Universitário Cassiano – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES)

Hilmara Aparecida Jesus Maioli, Universidade Federal do Espírito Santo

Unidade de Gestão da Qualidade e Segurança do Paciente, Hospital Universitário Cassiano Antonio de Moraes – HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Glaucia Cristina dos Santos França Sant’Ana, Universidade Federal do Espírito Santo

Unidade de Terapia Intensiva Neonatal, Hospital Universitário Cassiano -HUCAM, Universidade Federal do Espírito Santo – UFES, Vitória (ES)

Amábile de Sousa Cavalcante, Universidade Federal do Espírito Santo

Graduação do Curso de Fonoaudiologia, Universidade Federal do Espírito Santo – UFES, Vitória (ES), Brasil.

Citas

Maroja MCS, Silva ATMC, Carvalho AT. Iniciativa Hospital Amigo da Criança: uma análise a partir das concepções de profissionais quanto às suas práticas. Rev Port Saúde Pública. 2014; 32(1): 3-9. http://dx.doi.org/10.1016/j.rpsp.2014.02.002

Lau C. Breastfeeding Challenges and the Preterm Mother-infant Dyad: A Conceptual Model. Breastfeed Med. 2018; 13(1): 8-17. https://doi.org/10.1089/bfm.2016.0206

Bellù R, Condò M. Breastfeeding promotion: evidence and problems. Pediatr Med Chir. 2017; 39(2): 156. https://doi.org/10.4081/pmc.2017.156

McNair C, Campbell-Yeo M, Johnston C, Taddio A. Nonpharmacologic Management of Pain During Common Needle Puncture Procedures in Infants Current Research Evidence and Practical Considerations: An Update. Clin Perinatol. 2019; 46(4): 709-30. https://doi.org/10.1016/j.clp.2019.08.006

Nyqvist KH, Maastrup R, Hansen MN, Haggkvist AP, Hannula L, Ezeonodo A, et al. The Baby-friendly Hospital Initiative for Neonatal Wards. Core document with recommended standards and criteria. Nordic and Quebec Working Group; 2015. [cited 2022 Mai 23]; Available from: http://epilegothilasmo.gr/wp-content/uploads/2017/04/Neo_BFHI_Core_document_2015_Edition.pdf

Lubbe W, Ham-Baloyi WT. When is the use of pacifiers justifiable in the baby-friendly hospital initiative context? a clinician’s guide. BMC Pregnancy and Childbirth. 2017; 17(1): 130. https://doi.org/10.1186/s12884-017-1306-8

Ling HTB, Sum FHKMH, Zhang L, Yeung CPW, Li KY, Wong HM, et al. The association between nutritive, non-nutritive sucking habits and primary dental occlusion. BMC Oral Health. 2018; 18(1): 145. https://doi.org/10.1186/s12903-018-0610-7

Batista CL, Ribeiro VS, Nascimento MD, Rodrigues VP. Association between pacifier use and bottle-feeding and unfavorable behaviors during breastfeeding. J Pediatr. 2018; 94: 596-601. https://doi.org/10.1016/j.jped.2017.10.005

Sampaio RCT; Brito MBG; Siebra LGB; Gonçalves GKM; Feitosa DMA; Cabral KSSA; Pinto DM. Association between pacific use and breastfeeding interruption: A literature review. Brazilian Journal of health Review. 2020; 3(4): 7353-72. DOI:10.34119/bjhrv3n4-011

Rocha AD, Costa AM. Uso de luvas de látex em substituição às chupetas em Hospitais Amigos da Criança. Rev Ped SOPERJ. 2021; 21(3)98-106. DOI: http://dx.doi.org/10.31365/issn.2595-1769.v21i3p98-106

Dadalto ECV. Interação mãe-bebê e uso de chupeta no contexto do nascimento pré-termo: Cultura, representações sociais e processos proximais. [Tese]. Vitória (ES): Programa de Pós-graduação em Psicologia, Universidade Federal do Espírito Santo; 2014.

Associação Brasileira de Normas Técnicas. Norma Brasileira 10334 – segurança de chupetas. Rio de Janeiro: ABNT: 2003. 20p.

Agência Nacional de Vigilância Sanitária (ANVISA). Resolução nº 221. 05 de agosto de 2002. Publicada no D.O.U. de 06 de agosto de 2002.

Palosuo T, Antoniadou I, Gottrup F, Phillips P. Latex medical gloves: time for a reappraisal. Int Arch Allergy Imm 2011; 156(3): 234-46. doi: 10.1159/000323892

Álvarez D, Rojas H. Alergia al látex, puesta al día. Rev Chil Dermatología. 2016; 32(4): 192-96. DOI: http://dx.doi.org/10.31879/rcderm.v32i4.79

Kelly KJ, Sussman G. Latex allergy: where are we now and how did we get there? Internet J Allergy Clin Immunol Pract. 2017; 5(5): 1212–1216. DOI: 10.1016/j.jaip.2017.05.029

Ferreira AM, Andrade D. Avaliação Microbiológica de luvas de procedimento: considerações para seu uso na técnica de curativo. Rev. Enferm. UERJ. 2010; 18(2): 191-7.

Pereira CNP; Silva BVN; Menezes PHB; Pedro JPS; Silva NRD; Chagas HDS. Damage and benefits to the child’s health due to the use of pacifiers: what pediatricians need to know. Braz. J. of Develop. 2020; 6(12): 101520-31. DOI:10.34117/bjdv6n12-591

Marques AL; Alves MB; Firmo WDCA; Sabbadini OS. Avaliação da Integridade de Luvas de Procedimentos Novas Utilizando Micro-organismos. Ensaios e Ciência. 2021; 25(5): 809-14. DOI: https://doi.org/10.17921/1415-6938.2021v25n5-espp809-814

Thomas S, Agarwal M, Mehta G. Intraoperative glove perforation--single versus double gloving in protection against skin contamination. Postgrad Med J. 2001; 77(909): 458-60. doi: OI: 10.1136/pmj.77.909.458 .

Trindade JPDA; Serra JRD; Tipple AFV. Index of perforation of procedure/surgical gloves used by workers in the purging of a material and sterilization center. Texto & Contexto - Enfermagem. 2016,25(2), e1410015. Disponível em: <https://doi.org/10.1590/0104-07072016001410015>. Epub 7 Jul 2016. ISSN 1980-265X. https://doi.org/10.1590/0104-07072016001410015.

Oberg C; Schwartz JP; Zander GF; Ruan JD; Santos EB. Passagem de microrganismos através de luvas de procedimento e de luvas cirúrgicas antes de sua utilização. Rev. Odontol. UNESP. 2017; 36(2): 127-30.

Machado MB. Contribuições para a tecnovigilância das luvas de látex e a biossegurança. [Dissertação]. Ribeirão Preto (SP): Escola de Enfermagem de Ribeirão Preto, Universidade de São Paulo; 2019.

Pineda R; Luong A; Ryckman J; Smith J. Exploratory study found that pacifier use did not affect feeding performance in full-term newborn infants, but it was related to lower socioeconomic status. Acta paediatrica, Oslo. 2018; 107(5): 806-10. DOi: 10.1111/apa.14253.

Publicado

2023-08-02

Cómo citar

Nunes, J. de A., Pontes, M. B., Martins, S. W., Coimbra, N. Q. T. de, Maioli, H. A. J., Sant’Ana, G. C. dos S. F., & Cavalcante, A. de S. (2023). Los efectos nocivos del “Guante Chupete” de látex em La Unidad Neonatal. Distúrbios Da Comunicação, 35(2), e58329. https://doi.org/10.23925/2176-2724.2023v35i2e58329

Número

Sección

Comunicações